COA Peptide Checker
COA peptide checker: pick the fields on your certificate and see what each one means.
New to this? A COA, or certificate of analysis, is the lab report for a single batch of a peptide. This page walks through it one field at a time and says what each field means and what to check. It gives no verdict: only the lab that issued the report can confirm it.
Sources: FDA Q7 guidance, 2016.
What this certificate shows. Only the issuing lab can confirm it.
Pick or type what your COA shows. Each step explains the field and what to check. This tool does not check, vouch for or rank any COA, lab, seller or product.
1. Compound and mass
This is the name of the material that was tested. It should be the same name as on your vial.
A mass can be printed as an average weight, a monoisotopic mass, or an ion with a charge. Each one gives a different number for the same peptide.
Mass spectrometry (MS) reads the m/z of ions from a sample, which is their mass to charge ratio. A COA may print an m/z value or a mass worked out from it.
2. Purity percent
For an HPLC area percent, this is the share of the included peak area that is in the main peak. It does not tell you how much peptide the powder holds.
This is how the lab measured the percent. HPLC splits a sample into peaks as it runs through a column.
This is the UV light the detector used. The peptide bond absorbs near 210 to 220 nm, so peptides are usually read there.
3. Tests listed
This is the number the endotoxin test gave. Endotoxin comes from the outer wall of Gram-negative bacteria, E. coli for one.
This is the limit the result was tested against. FDA Q7 says a COA should list each test's acceptance limits.
4. Lot and dates
A lot or batch number is the code for one batch. This page asks only whether one is printed, never the number itself.
Compare the lot on the COA with the vial label, character by character. Watch for 0 and O, 1 and I.
This is the date printed for the tests or for the release of the batch. FDA Q7 lists the date of release as a COA field.
An expiry date is when the material should no longer be used. A retest date is when it should be checked again.
5. Lab
This is the lab named on the COA. Only the lab that issued the report can confirm it.
The list holds only labs whose own site showed a public lookup form when we checked. We checked 4 labs on October 6, 2026 and 2 labs on October 8, 2026. It is in A to Z order, says nothing about the quality of any lab's work, and is not an endorsement.
6. FDA Q7 field list
FDA Q7 is guidance for drug ingredient makers. A research product COA may not follow it. Its list is used here as a plain checklist of what a full COA holds.
What this certificate shows
Nothing is filled in yet. Each field you fill adds a line here.
Only the issuing lab can confirm it.
Use a point or a comma for decimals: 99.2 or 99,2. No spaces. Thousands commas work with a decimal point (4,113.6) or with two or more groups (1,000,000); a lone 1,000 is refused as unclear. Nothing you pick or type is saved, sent or printed.
Paste this code into your page. It shows the COA field explainer with one plain credit link.
Learn
Learn the basics: six short lessons
Six short lessons. Every demo uses sample data, not your COA. Nothing you tap is saved or sent.
A COA, or certificate of analysis, reports lab tests on one batch. It names the material, the batch number and the dates. It lists each test with its limit and its result. Only the lab that issued it can confirm the report.
Sample data. Tap a line.
Tap a line to see what it is for.
Check yourself
Who can confirm a COA?
HPLC is a way to split a sample into parts as it flows through a column. A detector reads each part as a peak. When purity is reported as an HPLC area percent, it is the share of the included peak area that is in the main peak. The lab leaves out peaks from solvent, reagents, mobile phase and the sample matrix, plus any peak at or below its cutoff.
Sample chromatogram. Tap a peak. Calculated here from made up peak areas: 12, 980 and 8.
Tap a peak to see its share of the area.
Check yourself
A COA reports 98 percent purity as an HPLC area percent. What is that 98 percent a share of?
Mass spectrometry (MS) measures ions made from the sample. It tells you the mass to charge ratio, written m/z. A peptide that picks up 3 protons shows up near (mass + 3 protons) divided by 3. So one peptide can give several numbers.
Sample: BPC-157. Tap a charge. Calculated here from the PubChem monoisotopic mass and the NIST proton mass.
Tap a charge to see the m/z number.
Check yourself
A COA prints a mass number with no label. What do you need to know first?
A lot or batch number is the code for one batch. FDA Q7 lists the batch number as a COA field. Compare the number on the COA with your vial label, character by character. Watch for 0 and O, 1 and I.
Sample lot codes, made up. Tap a pair.
Tap a pair to compare the two codes.
Check yourself
The lot on a COA and the lot on a vial differ by one character. What is the next step?
Several testing labs run a public lookup page. You type the codes from your COA, and the lab shows its own record. Find the lab's own website by searching its name yourself. If the lab's record differs from your COA, go by the lab's record.
Sample steps, with made up names and codes. Tap each one.
Tap a step to see what to do.
Check yourself
How should you get to the lab's lookup page?
Purity reported as an HPLC area percent does not tell you how much peptide the powder holds. A mass number does not show purity. A page of numbers cannot prove what is in a vial. Only the lab that issued the report can confirm it.
Sample COA lines, made up. Tap a line.
Tap a line to see what it covers.
Check yourself
A COA reports 99 percent purity as an HPLC area percent. How much of the powder's weight is peptide?
Sources: FDA Q7 guidance, 2016, for what a COA lists. US Pharmacopeia chapter 621, Chromatography, 2022 text, for the area percent and the peaks left out. The EMA guideline on synthetic peptides, 2025, for peptide content. USP chapter 736 for what MS measures. PubChem for the mass of BPC-157. NIST for the proton mass. Our own checks of lab sites on October 6, 2026 and October 8, 2026, for the lookup pages. The sample lines, peak areas and lot codes are made up for these lessons.
How this checker works
A COA, or certificate of analysis, is the lab report for a single batch. This checker walks through it one field at a time: the compound and its mass, the purity percent, the tests listed, the lot and dates, the lab, and the field list from FDA guidance. Each step says what the field means and what to check.
It never says a COA is good or bad. A page of numbers cannot prove what is in a vial. Only the lab that issued the report can confirm it. So the checker ends every path the same way: here is what the paper says, and here is whom to ask.
Sources: FDA Q7 guidance for makers of drug ingredients, 2016, for the field list in step 6 of the checker.
How to read a peptide COA, step by step
Work down the page in this order. It is the same order the checker uses.
- Find the compound name. It should be the same name as on your vial.
- Find the lot or batch number. Compare it with the vial label, one character at a time.
- Find the dates. Look for a test or release date and an expiry or retest date.
- Find who issued it. Look for the name of the lab or maker that issued the COA, with an address and a phone number.
- Read each test. Each one should list its method, its limit and its result.
- Read the purity percent. Note the method and the UV wavelength.
- Read the mass. Note whether it is an average weight, a monoisotopic mass or an ion.
- Ask the lab. Use the lab's own lookup page, or write to the lab.
The certificate of analysis page explains each part in more depth, with a sample layout.
Sources: FDA Q7 guidance, 2016, paragraphs 11.41 to 11.44, for the name, batch number, dates, tests and issuer details; Mant and others, 2007, for why the UV wavelength matters; PubChem for the two kinds of mass it lists.
What a full COA lists
The US Food and Drug Administration (FDA) publishes Q7, a guidance for makers of drug ingredients. Section 11.4 says what a certificate of analysis should show. A research product may not follow it, but it shows what a full report holds.
| Field | Q7 paragraph | Why it matters |
|---|---|---|
| Name of the material | 11.41 | Says what was tested |
| Batch or lot number | 11.41 | Ties the report to one batch |
| Date of release | 11.41 | Says when the batch was released |
| Expiry date. You may also find a retest date on the label, the COA or both | 11.41 | Says how long it should stay within limits, or when to check it again |
| Each test with its limit | 11.42 | A result needs a limit next to it |
| Number results | 11.42 | Numbers, not only "conforms" |
| Date and signature of authorized people in the quality unit | 11.43 | Shows who signed off, and when |
| Maker's name, address and phone. When a repacker or reprocessor ran the tests: that firm's name, address and phone, plus the maker's name | 11.43 | Says who made the batch and who tested it |
| Testing lab's name, address and phone (if a repacker, reprocessor, agent or broker issues a new COA, or has one issued for it) | 11.44 | Says whom to ask about the results |
| Reference to the original maker's name and address, and to the original batch certificate, with a copy attached (same case) | 11.44 | Points back to the maker and the maker's own certificate |
Q7 also says that, on request, certificates should be issued for each batch. If a COA names no batch, ask the issuer which batch it covers.
Sources: FDA Q7 guidance for makers of drug ingredients, September 2016, section 11.4, paragraphs 11.40 to 11.44.
What the purity percent means
A peptide COA may give purity by HPLC. HPLC is a way to split a sample into parts as it flows through a column. A detector reads each part as a peak. The purity percent is the share of the included peak area that is in the main peak. The lab does not count peaks that come from solvent, reagents, mobile phase or sample matrix. It also skips any peak at or below a cutoff it sets.
So 98 percent purity means the other counted peaks make up the last 2 percent of that area. That is all it means. It does not tell you how much of the powder is peptide. Water and salt in the powder are not counted in an area percent. That share has its own name: peptide content, or assay.
The wavelength matters too. Peptide bonds absorb UV light below 220 nm, so 210 to 220 nm is where labs usually read peptides. At 280 nm, only some amino acids absorb. Parts of a sample without them can be missed. The peptide purity page goes further, and the HPLC peptide testing page shows how the run works.
Sources: US Pharmacopeia chapter 621, Chromatography, 2022 text, for a peak's area as a percent of the included peak area; Mant and others, HPLC Analysis and Purification of Peptides, 2007, for the UV ranges; European Medicines Agency guideline on synthetic peptides, 2025, for peptide content.
What the mass number means
Mass spectrometry (MS) measures ions made from the sample. It tells you the mass to charge ratio, written m/z. An intact mass is a number you can compare with a molecule's mass. On its own, it does not establish identity or sequence. A COA might print one of three kinds of mass number.
- Average molecular weight (MW). It uses the natural mix of isotopes.
- Monoisotopic mass. It uses only the most common isotope of each element.
- An ion. A peptide that picks up 3 protons shows up near (mass + 3 protons) ÷ 3.
The checker compares the COA's number with PubChem, the public chemistry database from the US National Library of Medicine. It lists 33 peptides. First you pick what kind of number the COA printed. Then it shows the difference from the reference value. It never says what size of difference is acceptable. That depends on the instrument and method, and the lab should say.
Here is the catch. Anyone can look up a reference mass and print it on a document. So a small difference on paper does not show what is in a vial, and it does not show the document is accurate.
Sources: US Pharmacopeia chapter 736, Mass Spectrometry, public introduction, for what the method measures; European Medicines Agency guideline on synthetic peptides, 2025, on identity; PubChem for the reference masses, and its PUG REST documentation for what the average weight and the monoisotopic mass are.
Published masses for 33 peptides
We pulled each value from PubChem on 6 October 2026. The ion columns are worked out from the monoisotopic mass with this formula: m/z = (M + n × proton mass) ÷ n. The proton mass is 1.007 276 466 5789 u, from NIST. Tap a name to open its PubChem record.
| Compound | Formula | Average MW | Monoisotopic mass | [M+H]+ | [M+2H]2+ | [M+3H]3+ | [M+4H]4+ |
|---|---|---|---|---|---|---|---|
| AOD-9604 | C78H123N23O23S2 | 1815.1 | 1813.86035961 | 1,814.8676 | 907.9375 | 605.6274 | 454.4724 |
| BPC-157 | C62H98N16O22 | 1419.5 | 1418.70415882 | 1,419.7114 | 710.3594 | 473.9087 | 355.6833 |
| Bremelanotide (PT-141) | C50H68N14O10 | 1025.2 | 1024.52428442 | 1,025.5316 | 513.2694 | 342.5154 | 257.1383 |
| Cagrilintide | C194H312N54O59S2 | 4409 | 4406.2515111 | 4,407.2588 | 2,204.133 | 1,469.7578 | 1,102.5702 |
| Delta sleep-inducing peptide (DSIP) | C35H48N10O15 | 848.8 | 848.33006086 | 849.3373 | 425.1723 | 283.784 | 213.0898 |
| Desmopressin | C46H64N14O12S2 | 1069.2 | 1068.42695588 | 1,069.4342 | 535.2208 | 357.1496 | 268.114 |
| Elamipretide (SS-31) | C32H49N9O5 | 639.8 | 639.38566570 | 640.3929 | 320.7001 | 214.1358 | 160.8537 |
| Epitalon | C14H22N4O9 | 390.35 | 390.13867829 | 391.146 | 196.0766 | 131.0535 | 98.5419 |
| Exenatide | C184H282N50O60S | 4187 | 4184.0273075 | 4,185.0346 | 2,093.0209 | 1,395.683 | 1,047.0141 |
| GHRP-2 (pralmorelin) | C45H55N9O6 | 818.0 | 817.42753051 | 818.4348 | 409.721 | 273.4831 | 205.3642 |
| GHRP-6 | C46H56N12O6 | 873.0 | 872.44457755 | 873.4519 | 437.2296 | 291.8221 | 219.1184 |
| Glutathione | C10H17N3O6S | 307.33 | 307.08380644 | 308.0911 | 154.5492 | 103.3685 | 77.7782 |
| Hexarelin (examorelin) | C47H58N12O6 | 887.0 | 886.46022762 | 887.4675 | 444.2374 | 296.494 | 222.6223 |
| Ipamorelin | C38H49N9O5 | 711.9 | 711.38566570 | 712.3929 | 356.7001 | 238.1358 | 178.8537 |
| Kisspeptin-10 | C63H83N17O14 | 1302.4 | 1301.63054039 | 1,302.6378 | 651.8225 | 434.8841 | 326.4149 |
| Leuprolide | C59H84N16O12 | 1209.4 | 1208.64546218 | 1,209.6527 | 605.33 | 403.8891 | 303.1686 |
| Liraglutide | C172H265N43O51 | 3751 | 3748.9464612 | 3,749.9537 | 1,875.4805 | 1,250.6561 | 938.2439 |
| LL-37 | C205H340N60O53 | 4493 | 4490.5754259 | 4,491.5827 | 2,246.295 | 1,497.8658 | 1,123.6511 |
| Mazdutide | C207H317N45O65 | 4476 | 4473.2883156 | 4,474.2956 | 2,237.6514 | 1,492.1034 | 1,119.3294 |
| MOTS-c | C101H152N28O22S2 | 2174.6 | 2173.1077409 | 2,174.115 | 1,087.5611 | 725.3765 | 544.2842 |
| Octreotide | C49H66N10O10S2 | 1019.2 | 1018.44048069 | 1,019.4478 | 510.2275 | 340.4874 | 255.6174 |
| Oxytocin | C43H66N12O12S2 | 1007.2 | 1006.43645793 | 1,007.4437 | 504.2255 | 336.4861 | 252.6164 |
| Pramlintide | C171H267N51O53S2 | 3949 | 3946.9206749 | 3,947.928 | 1,974.4676 | 1,316.6475 | 987.7374 |
| Selank | C33H57N11O9 | 751.9 | 751.43407244 | 752.4413 | 376.7243 | 251.4853 | 188.8658 |
| Semaglutide | C187H291N45O59 | 4114 | 4111.1153770 | 4,112.1227 | 2,056.565 | 1,371.3791 | 1,028.7861 |
| Semax | C37H51N9O10S | 813.9 | 813.34796003 | 814.3552 | 407.6813 | 272.1233 | 204.3443 |
| Sermorelin | C149H246N44O42S | 3357.9 | 3355.8186992 | 3,356.826 | 1,678.9166 | 1,119.6135 | 839.962 |
| Survodutide | C192H289N47O61 | 4232 | 4229.0957042 | 4,230.103 | 2,115.5551 | 1,410.7058 | 1,058.2812 |
| Teriparatide | C181H291N55O51S2 | 4118 | 4115.1309424 | 4,116.1382 | 2,058.5727 | 1,372.7176 | 1,029.79 |
| Tesamorelin | C221H366N72O67S | 5136 | 5132.7166406 | 5,133.7239 | 2,567.3656 | 1,711.9128 | 1,284.1864 |
| Thymosin alpha-1 (thymalfasin) | C129H215N33O55 | 3108.3 | 3106.5041281 | 3,107.5114 | 1,554.2593 | 1,036.5087 | 777.6333 |
| Thymosin beta-4 | C212H350N56O78S | 4963 | 4960.4863169 | 4,961.4936 | 2,481.2504 | 1,654.5027 | 1,241.1289 |
| Tirzepatide | C225H348N48O68 | 4813 | 4810.5248574 | 4,811.5321 | 2,406.2697 | 1,604.5156 | 1,203.6385 |
A few names are missing on purpose. PubChem had no record for retatrutide under that name or its code name on the day we checked. Dulaglutide is a large fusion protein, not a short peptide. Some names cover more than one molecule, so we left them out.
Being on this list says nothing about a compound's use, legal status or quality. It is chemistry only.
Sources: Calculated here from PubChem monoisotopic masses, read 6 October 2026, and the NIST CODATA 2022 proton mass; the formula, average weight and monoisotopic mass columns are PubChem's own values.
Real or fake: what this checker will not say
A guide may promise to spot a fake COA. But paper can be edited. Logos can be copied. A QR code can point anywhere. No checklist can turn a PDF into proof.
What you can do is ask the lab that issued it. Several testing labs run a public lookup page. You type the codes from your COA, and the lab shows its own record. See COA verification for the labs we checked and what each page asks for.
If the lab's record and your PDF differ, go by the lab's record. If no lab is named, look for the maker's or issuer's contact details, and ask the seller who issued the COA.
Sources: Our own checks of testing lab websites on October 6, 2026 and October 8, 2026, for the public lookup pages.
Tests a COA may list besides purity
A report can list more than purity and mass. Here are five tests from the EU list for peptide medicines.
- Peptide content or assay. The share of the powder that is the peptide itself.
- Water content. Peptide powders can hold water from the air.
- Counterion. Many peptides come as salts. EU guidance names acetate as the usual counterion. TFA is another one.
- Bacterial endotoxins. A test for parts of bacteria cell walls. See endotoxin test.
- Sterility. A test for living microbes. It is not the same as the endotoxin test.
The peptide testing page covers each test and the guidance it comes from.
Sources: European Medicines Agency guideline on synthetic peptides, 2025, for the tests a peptide report may hold.
Questions
What is a COA for peptides?
A COA for peptides is one batch's lab report. It names the peptide, the batch number and the dates. It lists each test, its limit and its result, such as HPLC purity and mass. Only the lab that issued it can confirm the report.
How do you read a peptide COA?
Start with the name and batch number, and compare them with your vial. Then check the dates, the lab name, and each test with its limit and result. Read the purity method and wavelength, and the kind of mass number. Then ask the issuing lab to confirm it.
Is 98 percent purity good for a peptide?
This site does not judge purity numbers. Here is what 98 percent means: of the HPLC peak area the lab counted, the main peak holds 98 percent and the rest holds 2 percent. Peaks from the solvent, reagents, mobile phase and sample matrix are not counted, and neither is any peak at or below the lab's cutoff. It does not show peptide content, identity or endotoxin.
What is peptide COA testing?
Peptide COA testing is the lab work behind a certificate. A lab runs tests on a sample from one batch. Tests can include HPLC purity, peptide content, water, endotoxin and mass by mass spectrometry. The lab then reports each result next to its limit.
Sources: FDA Q7 guidance, 2016, for what a COA lists; US Pharmacopeia chapter 621, Chromatography, 2022 text, for the HPLC area percent and the peaks left out; European Medicines Agency guideline on synthetic peptides, 2025, for the tests named.
Sources
8 sources with read dates
- Q7 Good Manufacturing Practice Guidance for Active Pharmaceutical Ingredients, FDA, September 2016, section 11.4 and glossary, read 2026-10-06
- HPLC Analysis and Purification of Peptides, Mant CT and others, Methods Mol Biol 2007, PMID 18604941; full text read on PubMed Central (PMC7119934), read 2026-10-06
- General Chapter 621, Chromatography, harmonized text official 1 December 2022, United States Pharmacopeia; the copy of USP's own file kept by the Internet Archive on 7 December 2023, normalization procedure, read 2026-10-08
- Guideline on the Development and Manufacture of Synthetic Peptides, European Medicines Agency, EMA/CHMP/CVMP/QWP/367182/2025, in effect from 1 June 2026, read 2026-10-06
- General Chapter 736, Mass Spectrometry, United States Pharmacopeia, public introduction read 2026-10-06
- PubChem compound records, US National Library of Medicine; masses for 33 peptides read through the PubChem API on 2026-10-06
- PUG REST: compound property table, PubChem documentation, definitions of MolecularWeight and MonoisotopicMass, read 2026-10-08
- Proton mass in u, CODATA 2022, NIST, read 2026-10-06