Endotoxin Test
Endotoxin test is the short name for the bacterial endotoxins test, a lab test for parts of bacteria in a product.
Paste this code into your page. It shows the COA field explainer with one plain credit link.
Learn
The short version
Endotoxins are part of the outer cell wall of Gram-negative bacteria, such as E. coli. FDA describes them as a risk in injected drugs because they can set off an inflammatory response in the body. They can be present even when no living bacteria are.
On a peptide COA, the endotoxin line shows a result, a limit and a unit. This page explains each one. Our COA peptide checker can walk you through the endotoxin line on your own COA.
Sources: FDA presentation The Bacterial Endotoxins Specification: Points to Consider, for what endotoxins are and why they matter in injected drugs.
How the endotoxin test works
For over 30 years, FDA has accepted a test called LAL, short for Limulus amebocyte lysate. The lysate comes from the blood cells of the horseshoe crab. It reacts with endotoxin.
FDA lists three ways to read that reaction, all under USP chapter 85:
- Gel clot. The mix forms a firm gel if endotoxin is above a set level. It gives a yes or no at that level.
- Turbidimetric. The mix turns cloudy. A reader measures how fast.
- Chromogenic. The mix turns a color. A reader measures how fast.
The last two give a number. FDA guidance also lets firms use other validated methods if they work as well or better. A 2020 study describes one such option, recombinant factor C (rFC). It is a lab-made version of the crab protein that endotoxin switches on. The study notes that LAL can also react to substances called beta-glucans, while rFC is specific to endotoxin. FDA guidance adds that if results ever disagree, the USP gel clot method decides, unless the product's own standard says otherwise.
Sources: FDA guidance Pyrogen and Endotoxins Testing: Questions and Answers, 2026, background and question 5; FDA presentation on the endotoxins specification, for the three methods; the 2020 comparison of LAL and rFC tests in the journal Microorganisms.
What EU means
EU stands for endotoxin unit. It is the unit that endotoxin results and limits are written in. You will see it per mg of powder, per mL of solution, or per vial.
Units must match before you can compare two numbers. A result in EU per mg cannot be laid next to a limit in EU per mL without more facts, such as how much powder is in each mL. The checker does not convert between them.
A result written with a "less than" sign, such as < 0.5 EU per mg, means the test found less than that level. It is not a zero.
Sources: FDA presentation The Bacterial Endotoxins Specification, for the endotoxin unit and a limit written per mg; FDA Questions and Answers guidance, 2026, question 11, for limits written per mL.
Where the limit comes from
An endotoxin limit is not one number for every product. For injected products whose limits use body weight, FDA explains the formula from USP chapter 85: K ÷ M. K is a threshold listed in that chapter, in EU per kg of body weight per hour. M is the largest recommended amount of the product per kg of body weight. The same FDA slides list another K for products given by body surface area, in EU per square meter per hour.
So the limit depends on the product and how it is used. FDA guidance says the old table of limits from 1987 is out of date, and that limits should be worked out with the USP or AAMI method. This site does not work out limits or judge results. It explains what the numbers are.
Sources: FDA presentation The Bacterial Endotoxins Specification: Points to Consider, for the K ÷ M formula; FDA Questions and Answers guidance, 2026, question 7, for the 1987 table.
Endotoxin is not the same as sterility
A sterility test looks for living microbes. An endotoxin test looks for cell wall parts, alive or dead. FDA notes that most sterilization methods do not break down endotoxins. So a product can be sterile and still carry endotoxin. A COA needs both tests to speak to both questions. See peptide testing for the other tests a COA may list.
Sources: FDA presentation on the bacterial endotoxins specification, which says most sterilization methods do not inactivate endotoxins.
Reading the endotoxin line on a COA
Look for these parts.
- The method. Gel clot, turbidimetric, chromogenic, or another named method.
- The result, with its unit.
- The limit, in the same unit.
- The sample. What was tested: powder, a solution, or a whole vial.
- The batch number, so the result ties to your batch.
If a part is missing, ask the lab that ran the test. The COA verification page shows how, and the certificate of analysis page shows where each part sits on the page.
Sources: FDA presentation on the endotoxins specification, for the named methods; FDA Q7 guidance, 2016, for the result, limit and batch number fields.
Questions
What is an endotoxin test?
An endotoxin test, or bacterial endotoxins test, checks a product for endotoxin, a part of the cell wall of Gram-negative bacteria. The usual method uses LAL, a reagent from horseshoe crab blood cells. Results are given in endotoxin units (EU) next to a limit.
What is the LAL test?
The LAL test uses Limulus amebocyte lysate, made from horseshoe crab blood cells, which reacts with bacterial endotoxin. FDA lists gel clot, turbidimetric and chromogenic ways to read it, under USP chapter 85. FDA has accepted LAL in place of the rabbit pyrogen test for over 30 years.
Why do peptide COAs list endotoxin?
Endotoxin can be present even when no living bacteria are, and most sterilization methods do not remove it. So a full COA for a peptide meant to be injected lists an endotoxin result with its unit and limit. A research COA may not include it.
What does EU mean on an endotoxin test?
EU means endotoxin unit, the unit that endotoxin results and limits are written in. Results are given per mg, per mL or per vial. Compare a result only with a limit in the same unit.
Sources: FDA guidance Pyrogen and Endotoxins Testing: Questions and Answers, 2026, for LAL and the rabbit test; FDA presentation on the endotoxins specification, for the methods and sterilization; the 2020 LAL and rFC study, for where LAL comes from.
Sources
6 sources with read dates
- Pyrogen and Endotoxins Testing: Questions and Answers (Edition 2), FDA guidance for industry, March 2026, questions 5, 7 and 11, read 2026-10-06
- The Bacterial Endotoxins Specification: Points to Consider, Pfeiler E, FDA Center for Drug Evaluation and Research, read 2026-10-06
- Comparison of LAL and rFC Assays: Participation in a Proficiency Test Program between 2014 and 2019, Microorganisms 2020, PMID 32188126; full text read on PubMed Central (PMC7143553), read 2026-10-06
- Q7 Good Manufacturing Practice Guidance for Active Pharmaceutical Ingredients, FDA, September 2016, paragraphs 11.41 and 11.42, read 2026-10-06
- General Chapter 85, Bacterial Endotoxins Test, United States Pharmacopeia, public summary page read 2026-10-06
- Guideline on the Development and Manufacture of Synthetic Peptides, European Medicines Agency, EMA/CHMP/CVMP/QWP/367182/2025, section 4.4.1, read 2026-10-06