Certificate of Analysis
Certificate of analysis, or COA, is the name for a lab report on one batch of a product.
Paste this code into your page. It shows the COA field explainer with one plain credit link.
Learn
The short version
It says what was tested, which batch it came from, when it was tested, what each test was, the limit for each test, and the result. So COA testing means the tests a lab ran on one batch, and the COA is the report of those tests. Makers of drugs, chemicals, food and lab supplies all use them. In the US, FDA guidance for drug ingredient makers spells out what a COA should hold.
A COA is a claim about a batch. It is not proof on its own. The lab or maker that issued it is the one that can confirm it. To read your own COA field by field, use the COA peptide checker.
Sources: FDA Q7 guidance for makers of drug ingredients, 2016, which has a section on certificates of analysis.
What a COA lists, field by field
The FDA guidance called Q7 covers how drug ingredients are made and tested. Its section 11.4 is about certificates of analysis. Here is what it asks for, in plain words.
- The name of the material. Where it applies, also the quality standard it was made to.
- The batch number. Q7 defines a batch as an amount made so that it should be the same all the way through. The batch number is a unique code for it.
- The date of release. The date the batch was released.
- An expiry date or a retest date. An expiry date marks when the material should no longer be used, and a retest date marks when it should be checked again. Q7 asks for an expiry date on both the label and the COA. A retest date may sit on the label, the COA or both.
- Each test, with its limit. Q7 calls the limits acceptance criteria. They can be a range, a number or another clear measure.
- The results. Numbers, where the test gives numbers.
- A date and a signature. From authorized people in the quality unit, the team that is separate from production.
- The maker's name, address and phone number. When a repacker or reprocessor ran the tests, Q7 asks for that firm's name, address and phone number, and for the original maker's name.
- The testing lab's name, address and phone number. Only in one case: Q7 asks for this when a new COA is issued by or for a repacker, reprocessor, agent or broker.
- A reference to the original maker and the original certificate, with a copy attached. In that same case, Q7 says the new COA should give the original manufacturer's name and address. It should also refer to the original batch certificate and come with a copy of it.
Q7 also says a COA should be issued for each batch, on request. If a COA has no batch number, ask the issuer which batch it covers.
Sources: FDA Q7 guidance, September 2016, section 11.4, and its glossary for the words batch, expiry date, retest date and quality unit.
What a sample COA looks like
COAs differ in layout. This sample shows one way to order the parts. The values are placeholders, not results.
| Part of the page | What it shows |
|---|---|
| Header | Lab or maker name, address, phone, report number |
| Product block | Material name, batch number, amount received |
| Dates | Date received, date tested, date released, expiry or retest date |
| Test table | One row per test: test name, method, limit, result |
| Notes | How the sample was handled, and any limits of the tests |
| Sign off | Name, role, signature and date of the person who approved it |
For peptides, the test table may hold HPLC purity, mass by mass spectrometry, peptide content, water and endotoxin. The peptide testing page explains each one.
Sources: A sample layout written for this page, not a copy of any lab's report; European Medicines Agency guideline on synthetic peptides, 2025, for the peptide tests named under it.
COA vs COC and COA vs SDS
These three papers are easy to mix up.
- A COA lists test results for one batch. It shows numbers next to limits.
- A COC, or certificate of conformance, is a signed statement that goods meet the order's requirements. The US federal contract rule for it gives the wording: the supplier certifies the goods conform to the contract. It does not have to list test numbers.
- An SDS, or safety data sheet, is about hazards. Under the OSHA rule, it has 16 sections, such as hazards, handling, storage and first aid. It is about the chemical in general, not one batch.
So if you want the numbers for your batch, you want the COA.
Sources: Federal Acquisition Regulation 52.246-15, Certificate of Conformance; OSHA brief 3514 on safety data sheets; FDA Q7 guidance, 2016, for the COA.
Where a COA can fall short
A COA is only as good as the lab and the paper trail behind it. Watch for these gaps.
- No batch number, or one that differs from your vial. Ask the lab which batch the report covers.
- No lab name. Look for the maker's or issuer's contact details.
- Results with no limits. Ask what limit each result was held to.
- A purity with no method. Ask how it was measured.
- Dates that do not add up, such as a test date in the future.
None of these prove anything about the product. They are reasons to ask the lab. The COA verification page shows how.
Sources: FDA Q7 guidance, 2016, paragraphs 11.41 and 11.42, for the batch number and the limits a COA should show; the list of gaps is this site's own.
How a COA relates to purity and identity
Purity and mass are two numbers on a peptide COA. They answer different questions. Purity asks how large the main peak is next to all the included peak area. Mass gives a mass to charge result that can be compared with the expected molecular mass; by itself, it does not establish which molecule is present. Neither one tells you how much peptide is in the powder. Purity is usually read by HPLC with a UV detector near 210 to 220 nm, where the peptide bond absorbs. The peptide purity page explains why.
Sources: US Pharmacopeia chapter 621, Chromatography, 2022 text, for purity as a share of peak area; Mant and others, 2007, for the UV range used for peptides; European Medicines Agency guideline on synthetic peptides, 2025, on what a mass result can show.
Questions
What does COA stand for?
In lab and product quality work, COA stands for certificate of analysis. It is a report of the test results for one batch of a product. The letters can mean other things in other fields, such as accounting, so look at the context.
What is a certificate of analysis?
A certificate of analysis is a lab report for one batch. It names the product and batch, gives the dates, and lists each test with its limit and result. FDA guidance says it should be dated, signed by the quality unit, and name who made the batch.
What is the difference between a COA and a COC?
A COA lists the test results for a batch, with numbers next to limits. A COC, or certificate of conformance, is a signed statement that the goods meet the order's requirements. A COC does not have to show test numbers.
How do you get a certificate of analysis?
Ask the seller or maker for the COA that matches your batch number. FDA Q7 says makers of drug ingredients should issue one for each batch on request. Then check the batch number against your label and ask the lab named on it to confirm the report.
How to download COA Certificate online?
Ask the seller or maker for the COA file that matches your batch number. Some labs also run a lookup page where you type the codes printed on the COA and see the lab's own record. The COA verification page lists labs that had one when we checked.
Sources: FDA Q7 guidance, 2016, paragraphs 11.40 to 11.43, for the COA answers; Federal Acquisition Regulation 52.246-15 for the certificate of conformance.
Sources
6 sources with read dates
- Q7 Good Manufacturing Practice Guidance for Active Pharmaceutical Ingredients, FDA, September 2016, section 11.4 (paragraphs 11.40 to 11.44) and glossary, read 2026-10-06
- FAR 52.246-15, Certificate of Conformance, Federal Acquisition Regulation, acquisition.gov, read 2026-10-06
- Hazard Communication Standard: Safety Data Sheets (OSHA 3514), Occupational Safety and Health Administration, read 2026-10-06
- Guideline on the Development and Manufacture of Synthetic Peptides, European Medicines Agency, EMA/CHMP/CVMP/QWP/367182/2025, read 2026-10-06
- HPLC Analysis and Purification of Peptides, Mant CT and others, Methods Mol Biol 2007, PMID 18604941; full text read on PubMed Central (PMC7119934), read 2026-10-06
- General Chapter 621, Chromatography, harmonized text official 1 December 2022, United States Pharmacopeia; the copy of USP's own file kept by the Internet Archive on 7 December 2023, normalization procedure, read 2026-10-08